Background in R&D:
The thermostatic gas water heater’s main part has always been the gas proportional valve. Its primary job is to regulate the proportional valve’s output pressure in accordance with the input current and to stabilize that pressure. The usability and safety of the thermostatic gas water heater are directly impacted by the gas proportional valve’s quality. It serves as the gas water heater’s main part.


Product Detail

Product Tags

R&D background

Background in R&D:
The thermostatic gas water heater's main part has always been the gas proportional valve. Its primary job is to regulate the proportional valve's output pressure in accordance with the input current and to stabilize that pressure. The usability and safety of the thermostatic gas water heater are directly impacted by the gas proportional valve's quality. It serves as the gas water heater's main part.

Second, the gas proportional valve is mainly used:
1.Proportional adjustment technology: The proportional valve changes the size of the magnetic field through the proportional valve coil according to the current input by the circuit. The moving shaft (material is pure iron) in the center of the proportional valve coil is moved up and down by the force of the magnetic field, thereby driving and moving the shaft. The connected valve assemblies move up and down, and the ventilation area matched by the spherical surface of the valve assembly and the proportional valve body changes as the valve assembly moves up and down, and finally changes the output pressure of the proportional valve. The output pressure of the proportional valve is proportional to the proportional valve current. increase and increase;

04-03

Installation Dimensions

Application Fields Of Gas Valve

FUEL HEATERS

makes living more comfortable and the heater safer.

BUSINESS KITCHENWARE

Ensure the security of commercial kitchen equipment.

BREAD MACHINE

Make baked goods more savory.

BRIGHT COOKER

Let your kitchen tools get to know you better.

Model WB04-03  
Gas Source LPG/NG
Max. Pressure 5KPa
Open Working Voltage ≤168V
Off Release Voltage ≤32V
Outer Leakage 20ml/min
Inner Leakage 20ml/min
Envoirment temperature -20~60℃
Rated Voltage 220V
Voltage of proportional valve 24V